WALL LININGS - Simple Solutions - Thinner Wall Solutions - No Wet Trades - Greater Wall Heights - Easily meets Building Regulations and Design guides such as BB93 & HTM56 or 2045
Independant Wall Linings
XPR System | Fire Protection | Improved Sound Insulation ΔR'w | Stud Depth | Max Height of Wall | Weight of Wall | Wall Thickness | WL1
| 30 mins
| 20 dB | 50mm
| 3 metres * | approx 23kg/m² | ≥ 75mm | WL2
| 60 mins
| 22 dB | 50mm
| 3 metres *
| approx 41kg/m² | ≥ 90mm |
Adjustable Wall Linings
XPR System | Fire Protection | Clip Depth | Max Height of Wall | Weight of Wall | Wall Thickness | WL3
| 30 mins
| 30/60/125mm | 5 metres * | approx 23kg/m² | 42.5-137.5mm | WL4
| 60 mins
| | 5 metres *
| - | 55-150mm |
Metal Furring Lining
XPR System | Fire Protection | Furring Depth | Max Height of Wall | Weight of Wall | Wall Thickness | WL5
| 30 mins
| 15.5mm | As Required | approx 18kg/m² | 28mm |
* For Greater heights, technical details are available upon request. |
|
 |
|
|
|
|  |